Life Safety

System Specialists

  • Analogue Fire Detection
    Syncro ASSyncro AS ListecSyncroSyncro ViewSyncro MatrixSyncro IdentSyncro ModulesMulti Input/ Output UnitsSyncro I/O Boards & EnclosuresSyncro GUIDE
  • Conventional Fire Detection
    Sigma CPSigma CP-ASigma CP-RSigma CP AncillariesSigma MatrixK3000 SeriesLCMU
  • Extinguishant Control Panels
    Sigma XTSigma XT+Sigma XT+ CoincidenceSigma SiSigma XT Keyswitches & AncillariesSyncro XT+Syncro Si
  • Power Supplies & Battery Chargers
    Power Supplies & Battery Chargers2.5 & 5.25Amp PSUs10.25Amp PSU
  • Miscellaneous
    Sigma DocBoxTamper Resistant Vision WindowWarning signsRemote Isolate/ Audio VisualRemote Indicator UnitsWater DetectionSyncro As Printer Enclosure
  • UL/ FM Approved Panels
    Analogue Addressable Control PanelsEliteElite RSeVieweMatrixeNet16 Channel IO BoardConventional Control Panels
    Sigma A-CPSigma A-CP AnnunciatorExtinguishant Control PanelsSigma A-XTSigma A-Si Sigma A-XT Keyswitches & AncillariesPower Supplies10.25Amp PSU
  • Custom Engineered Solutions
  • Marine
    Syncro ASMSyncro View MarineSyncro ASM Voyage Data Recorder (VDR)

Syncro IO

16 Channel

Input/Output Unit

  • To add more I/O capability to the extensive options already offered by the Syncro control panel, up to thirty two, sixteen channel I/O boards may be connected.
  • The 16 channel boards may be mixed on the RS485 bus with 8 way sounder boards, 6 way sounder boards or 4 way conventional detection zone boards to provide a very flexible system of I/O to satisfy any requirement.
  • When using a simple two wire RS485 communications protocol, these boards may be mounted locally to the control panel or distributed on a bus up to 1200 metres long by using a suitable cable.
  • The flexibility of these boards is further enhanced by the fact that each of the channels is configurable as either an input or and output.
  • Each channel may also be configured to produce a variety of input actions or respond to a variety of output types.
  • All channels can contribute to, or respond to, system wide cause and effects logic.
  • Typical uses for I/O boards include geographical LED mimic displays and plant alarm inputs.
  • Standard Syncro control panels contain fixings for one sounder, relay, conventional detection or I/O board, which can easily be connected using four small signal wires to the power and comms bus within the panel.
  • Consideration must be taken as to the loading on the main panel.

Documentation

  • Data Sheet

    DS22 Data Sheet (16 Channel)
  • Manuals

    Man-1056 Main Manual (16 Channel)
Quick Links

Request a

Price List

"In The Loop"

Email Newsletter Registration

"In The Loop"

Email Archive

"Technical  Loop"

Email Archive

Request Product

Support CD

Download Kentec

Brochure

Events Kentec

are attending

Download

Product Manuals

Taktis e-Learning

8 Way Extender Board

  • To further enhance the versatility of the Syncro fire alarm system, additional relay output capability can be added using Syncro relay boards.
  • These boards have 8 voltage free changeover relay contacts, each of which can be individually programmed.
  • Up to 32 of these boards can be connected to the dedicated RS485 communications bus in the control panel giving the capability of up to 256 additional relay outputs.
  • The relay boards may be mixed on the RS485 bus with 16 channel I/O boards, 6 way sounder boards or 4 way conventional detection zone boards to provide a very flexible system of I/O to satisfy any requirement.
  • All outputs are configurable in the same way as devices connected to the loops and all may be acted upon by cause and effect logic.
  • These boards are typically used in applications which require more than the four standard relay outputs such as signalling to other systems or plant control.
  • Standard Syncro control panels contain fixings for one sounder, relay, conventional detection or I/O board, which can easily be connected using four small signal wires to the power and comms bus within the panel.
  • Consideration must be taken as to the loading on the main panel.

Documentation

6 Way Sounder

Extender Board

  • To further enhance the versatility of the Syncro fire alarm system, additional sounder output capability can be added using Syncro sounder boards.
  • These boards have 6 monitored sounder outputs, each of which can be individually programmed.
  • In addition to the sounder outputs each board has two general purpose, opto-isolated inputs and two volt-free changeover contact outputs.
  • Up to 32 of these boards can be connected to the dedicated RS485 communications bus in the control panel giving the capability of 192 additional sounder outputs with 64 general purpose inputs and 64 general purpose outputs.
  • The sounder boards may be mixed on the RS485 bus with 16 channel I/O boards, 8 way relay boards or 4 way conventional detection zone boards to provide a very flexible system of I/O to satisfy any requirement.
  • All inputs and outputs are configurable in the same way as devices connected to the loops and all may contribute to, or be acted upon by cause and effect logic.
  • These boards are typically used in applications that require more than the four standard sounder outputs such as replacement of existing conventional systems.
  • Standard Syncro control panels contain fixings for one sounder, relay, conventional detection or I/O board, which can easily be connected using four small signal wires to the power and comms bus within the panel.
  • Consideration must be taken as to the loading on the main panel.

Documentation

4 Way Conventional

Detection Zone Module

  • To further enhance the versatility of the Syncro fire alarm system, four conventional detection circuits can be connected with up to 30 detectors per circuit.
  • Conventional control panels can be replaced with this simple module and existing conventional systems can be interfaced directly to modern analogue addressable control systems and networks.
  • A fail safe mode ensures that the detection inputs will still operate the sounder outputs and fire contact if communication to the Syncro panel is lost.
  • Up to 32 of these boards can be connected to the dedicated RS485 communications bus in the control panel giving the capability of up to 128 conventional zones with 64 sounder outputs.
  • The detection zone boards may be mixed on the RS485 bus with 16 channel I/O Boards, 6 way sounder boards or 8 way relay boards to provide a very flexible system of I/O to satisfy any requirement.
  •  All inputs and outputs are configurable in the same way as devices connected to the loops and all may be acted upon by cause and effect logic.
  • Standard Syncro control panels contain fixings for one (four way) Detection Zone board, Sounder board, Relay board or I/O board, all of which can easily be connected using four signal wires to the power and comms bus within the panel.
  • Consideration must be taken as to the loading on the main panel.

Documentation

I/O Board Enclosure

  • A range of new enclosures designed to house Syncro I/O modules with or with a power supply. The Syncro I/O enclosure offers the installer the flexibility to create their own customised I/O panel. The standard Syncro I/O enclosure can hold up to 3 Syncro I/O modules or 2, if a power supply is incorporated.

Documentation

Addressable Sounder Controller Unit

  • Syncro addressable sounder controller units enable additional, distributed power and control for sounder circuits in situations where there are insufficient circuits at the fire alarm control panel or where additional power is required to power heavily loaded sounder circuits.
  • Sounder control modules for any of the protocols supported by Syncro are available in a steel enclosure designed to match the appearance of the Syncro fire alarm control panel.
  • All units contain mains powered battery charger/power supply, they have space for up to 7 Ah batteries.
  • Indicators are provided for power healthy and power fault conditions and power fault conditions are signalled to the Syncro fire alarm control panel as a sounder fault.